Choose among three calculations: one cable in a duct, several cables in a duct, or ducts in a conduit with optional cables beside them. Publishers' pages were read November 15, 2026; offered dimensions come from makers, distributors and reference sites.
Changing units reinterprets typed numbers without converting them and recomputes all three results. HDPE choices retain source inches at three decimals; microduct names use millimeters. HDPE bores in millimeters and microduct bores in inches show 'converted' beside the value. These and computed lengths use the chosen unit: three decimals in inches, two in millimeters. Computed lengths carry no 'converted' label.
Enter the cable's outside diameter, a duct and a publisher's marks or your own. A mark is a comparison figure. Results show area fill, diameter ratio, the fit and, with marks chosen, the comparison. Only an upper mark including equality gives the largest cable outside diameter for this duct and smallest duct inside diameter for this cable at that mark, rounded down and up respectively. Blue Diamond Industries' and CBS Products' marks give neither dimension.
Typed starting values are example inputs that show a result. Reset restores them; offered ducts and chosen marks are not example inputs.
Enter the outside diameter from your cable's data sheet. No cable sizes are provided to choose from.
SDR 11 and 13.5 bores at 3/4 in and 5 in are withheld: no two separate sources agree, and their dimensions differ by more than 0.002 in. Enter the maker's inside diameter for your pipe.
Use the maker's data sheet for a duct outside the lists. Its inside diameter must exceed every item's outside diameter.
Enter an upper mark, with an optional lower mark below it: each greater than 0 and less than 100, at most one decimal. The basis is areas, or diameters when chosen in the first calculation.
No single fill rule exists for fiber. Publishers' recommended marks use stated area or diameter bases; none is a code requirement. The tool gives no verdict. Publishers' pages were read November 15, 2026; dimensions come from makers, distributors and reference sites. No code or standard was read for a limit. Engineer confirmation is pending. Results omit all factors listed below, including tolerance and ovality.
Microduct 14/10 mm; nominal inside diameter converted to 0.394 in.
One item: smaller than the bore. Several items: proven to lie side by side in the bore with no clearance. This says nothing about installation.
63.5% is within the chosen marks, using their area or diameter basis and comparing result and marks at one decimal.
Dura-Line, a duct maker, states diameter-based marks for jetting one micro cable into a microduct.
Enter cable diameters, quantities and a duct. See area fill, fit and the largest cable's diameter ratio, without comparison. Optionally compare area fill with your own marks; none of the publishers whose pages were read supplies marks for several cables in one duct.
Typed starting values are example inputs that show a result. Reset restores them; offered ducts and chosen marks are not example inputs.
Enter up to 6 rows.
SDR 11 and 13.5 bores at 3/4 in and 5 in are withheld: no two separate sources agree, and their dimensions differ by more than 0.002 in. Enter the maker's inside diameter for your pipe.
Use the maker's data sheet for a duct outside the lists. Its inside diameter must exceed every item's outside diameter.
Your marks use areas here. A diameter basis is available only for one cable in the first calculation.
Enter an upper mark, with an optional lower mark below it: each greater than 0 and less than 100, at most one decimal. The basis is areas, or diameters when chosen in the first calculation.
No single fill rule exists for fiber. Publishers' recommended marks use stated area or diameter bases; none is a code requirement. The tool gives no verdict. Publishers' pages were read November 15, 2026; dimensions come from makers, distributors and reference sites. No code or standard was read for a limit. Engineer confirmation is pending. Results omit all factors listed below, including tolerance and ovality.
HDPE SDR 11, nominal 2 in; printed inside diameter 1.917 in.
One item: smaller than the bore. Several items: proven to lie side by side in the bore with no clearance. This says nothing about installation.
Add HDPE ducts by size, microducts by name, or ducts by outside diameter, with quantities; cables may lie beside them. Select or enter the conduit. See area fill, fit and comparison with your area marks or Dura-Line's existing-conduit mark, available only with a duct row.
Typed starting values are example inputs that show a result. Reset restores them; offered ducts and chosen marks are not example inputs.
Enter up to 6 rows.
SDR 11 and 13.5 bores at 3/4 in and 5 in are withheld: no two separate sources agree, and their dimensions differ by more than 0.002 in. Enter the maker's inside diameter for your pipe.
Enter the inside diameter from the maker's data sheet for an unlisted conduit. Every item must be smaller than that bore.
Your marks use areas here. A diameter basis is available only for one cable in the first calculation.
Enter an upper mark, with an optional lower mark below it: each greater than 0 and less than 100, at most one decimal. The basis is areas, or diameters when chosen in the first calculation.
No single fill rule exists for fiber. Publishers' recommended marks use stated area or diameter bases; none is a code requirement. The tool gives no verdict. Publishers' pages were read November 15, 2026; dimensions come from makers, distributors and reference sites. No code or standard was read for a limit. Engineer confirmation is pending. Results omit all factors listed below, including tolerance and ovality.
Conduit: HDPE SDR 11, nominal 4 in; printed inside diameter 3.633 in.
One item: smaller than the bore. Several items: proven to lie side by side in the bore with no clearance. This says nothing about installation.
62.6% is at or above the upper mark, comparing result and mark on the mark's area or diameter basis at one decimal.
Area fill compares the items' combined cross-sections with the bore's cross-section. Diameter ratio compares one item's outside diameter with the bore's inside diameter. Fit asks whether the set can lie in the bore: proven either way, or unproven. Percentages round half up to one decimal. Comparison uses area fill for area-based marks and diameter ratio for diameter-based marks, with results and marks compared as printed at one decimal.
A = 100 x (n1 x d1^2 + n2 x d2^2 + ...) / D^2
R = 100 x d / DA means area fill as a percentage; R means diameter ratio as a percentage. For each row, n is the quantity and d is the item's outside diameter. D is the bore's inside diameter. The area formula combines row cross-sections. The diameter formula describes exactly one item.
No single fill rule exists for fiber. Publishers' marks differ by source and basis. The same number on an area basis and a diameter basis means different amounts: a diameter ratio of 70% gives a computed area fill of 49%. A figure without a known basis cannot support comparison. Five of the nine statements below supply comparisons; the other four are shown only and never used for comparison.
| Publisher | Publisher Kind | Figure | Basis | Applies To | Installation Method | Conditions | Page Content Date |
|---|---|---|---|---|---|---|---|
| Dura-Line | Duct maker |
| Diameter ratio | Jetting a single micro cable into a microduct. | Jetting |
| January 28, 2026 |
| Blue Diamond Industries | Duct maker |
| Diameter ratio | Blowing microcables into a microduct. | Blowing |
| No publication or revision date for this content was recorded. |
| Equipment maker |
| Area fill | Blowing a single cable into either an innerduct or a microduct. | Blowing |
| March 2, 2020 |
| Plastics Pipe Institute | Trade association |
| Diameter ratio | Pulling a single cable into an innerduct whose bore is two times the cable's outside diameter. | Pulling |
| No publication or revision date for this content was recorded. |
| Dura-Line | Duct maker | Area fill | Subdividing existing conduit with innerducts, microducts and cables. The subdividing explainer gives the mark; the OverRide calculator establishes the area basis. The pages do not specify an installation method. | Method not stated |
| April 13, 2026 | |
| United Poly Systems (Atkore) | Duct maker |
|
| Jetting installations. | Jetting | No conditions attached on the page. | No publication or revision date for this content was recorded. |
| The Fiber Optic Association | Trade association |
|
| Installing into microduct by jetting or blowing. | Jetting or blowing |
| No publication or revision date for this content was recorded. |
| The Fiber Optic Association | Trade association |
|
| Hauling is the publisher's term for the installation method, interpreted here as pulling. | Hauling, the publisher's term, interpreted here as pulling |
| No publication or revision date for this content was recorded. |
| Plastics Pipe Institute | Trade association |
|
| The page states neither an application nor an installation method for these figures. Readers can interpret the surrounding discussion as concerning innerducts inside a casing pipe; the publisher does not state that setting for the figures. | Method not stated |
| No publication or revision date for this content was recorded. |
The electrical code, TIA-569, the BICSI manual and cable makers' application notes were not read, so none is used here.
The 20 HDPE choices use SDR 11, 13.5 and 17 and average or nominal bores printed by makers, distributors and reference sites. Subtracting two minimum wall thicknesses from outside diameter gives a bore larger than those printed values; this page excludes it (2 in SDR 11: 1.943 in; 4 in SDR 11: 3.682 in). A size requires matching figures from separate sources (identical maker and distributor tables count once), or two separate sources within 0.002 in, choosing the smaller except for 3 in SDR 11: 2.826 in replaces 2.825 in. SDR 11 and 13.5 bores at 3/4 in and 5 in are withheld because separate sources disagree beyond 0.002 in; enter the maker's bore.
Microduct names give outside and nominal inside diameters in millimeters: 5/3.5, 7/3.5, 7/4, 8/6, 10/6, 10/8, 12/8, 12/10, 12.7/10, 14/10, 16/12, 16/13, 18/14, 22/16, 27/20. The tool uses nominal bores. For 14/10, one maker prints a minimum inside diameter of 9.8 mm; another prints an inside diameter of 9.90 mm without calling it a minimum. Both are below the nominal 10 mm used here. Read Innerduct for Fiber Conduit: HDPE, Fabric and Sizing Decisions and Microduct for Air-Blown Fiber: Sizes, Bundles and Construction Decisions.
No result takes the factors below into account. These include dimensional tolerance and ovality as well as factors affecting installation.
Electrical code fill percentages apply to optical fiber cable sharing a raceway with electrical conductors. They are not a code requirement for optical fiber cable alone. This statement rests on public paraphrases of the code that word the condition differently. The code itself was not read; an engineer's confirmation is pending. The Conduit Fill Chart and Calculator gives the electrical code's fill rules for electrical raceways.
In millimeters, a 6 mm cable is an example input in the offered 14/10 microduct: area fill 36.0%, diameter ratio 60.0%; Dura-Line's upper diameter mark is 75%, and at the upper mark, the largest cable outside diameter for this microduct is 7.50 mm and smallest duct inside diameter for this cable is 8.00 mm. The 60.0% diameter ratio lies within Dura-Line's diameter marks, lower 50% and upper 75%, including equality, for jetting a single micro cable into microduct.
In inches, three cables of 0.5 in and two of 0.3 in are example inputs in SDR 11 2 in duct: area fill 25.3%, largest cable's diameter ratio 26.1%, without comparison. They are proven to lie side by side with no clearance; no publisher read supplies several-cable marks.
Three HDPE 1-1/4 in innerducts, outside diameter 1.660 in, in SDR 13.5 4 in conduit, bore 3.793 in, give area fill 57.5%, above Dura-Line's 55% area mark for subdividing existing conduit with innerducts, microducts and cables. They are proven to lie side by side with no clearance. These are tool computations.
The marks come from publishers' pages read on November 15, 2026; dimensions come from makers, distributors and reference sites. A mark supports comparison only when its publisher states it in its own name and gives its basis in words. Other statements are displayed without comparison. Arithmetic was checked against published worked examples; where an example's digits do not follow from its inputs, the tool follows the arithmetic. The packing factors for 1 to 12 equal items come from 2 references. The electrical code, TIA-569, the BICSI manual and cable makers' application notes were not read. An engineer's confirmation of the figures is pending.
Conduit Fill Chart and Calculator: look up same-size conductor counts or calculate mixed conductor fill, the electrical code's applicable limit for electrical conductors and the smallest passing raceway size. Voltage Drop Calculator: calculate voltage drop, the smallest wire size or longest one-way run within your limit for copper or aluminum. Fiber Color Code Chart: look up fiber locations, tube positions, color references and ribbon charts.
Continue with Conduit Fill Ratio Design Guide for Fiber Networks: Sizing, Standards, and Common Mistakes. Explore Draftech International's conduit and duct bank design page, Underground Fiber Duct Design Services for Telecom Conduit Systems, or its LLD services page, Low Level Design Engineering That Builders Can Work From. Review the free design offer.
The count depends on the cables' outside diameters, the bore and whose marks are applied; the tool computes results for your figures. In inches, three cables of 0.5 in and two of 0.3 in are an example input set in the offered SDR 11 2 in duct, whose inside diameter is 1.917 in. The area fill is 25.3%; the largest cable's diameter ratio is 26.1%, without comparison. The set is proven to lie side by side with no clearance. No marks are selected; none of the publishers whose pages were read supplies marks for several cables in one duct.
None of the table's nine statements gives 40 percent as a fiber fill mark. The electrical code's 40% figure concerns three or more conductors in a raceway, as the conduit fill chart states. Electrical code fill percentages apply to fiber sharing a raceway with electrical conductors; they are not a code requirement for fiber alone. No single fill rule exists for fiber. Compared marks are recommendations from named duct makers, equipment makers or trade associations, on each publisher's stated area or diameter basis. They differ; none is a code requirement. The tool gives no verdict of its own.
Electrical code fill percentages are not a code requirement for optical fiber cable alone. They apply when optical fiber cable shares a raceway with electrical conductors. This statement rests on public paraphrases of the code, which word the condition differently from one another. The code itself was not read; an engineer's confirmation is pending.
For HDPE 1-1/4 in innerducts, each outside diameter is 1.660 in. The offered SDR 11 4 in conduit has a bore of 3.633 in. Three is the largest count proven to lie side by side with no clearance. Area fill is 62.6%, above Dura-Line's 55% area mark for subdividing existing conduit with innerducts, microducts and cables. Four are proven not to fit: they require a bore of at least 4.0076 in, so no comparison against the mark is shown. These are tool computations for these dimensions; use the tool for other counts, sizes and conduits. A fit says nothing about installation.
For jetting a single micro cable into microduct, Dura-Line gives diameter marks: lower 50%, upper 75%, both including equality. For blowing microcables into microduct, Blue Diamond Industries gives diameter reference marks of 50%, 65% and 75%, the last restricted to perfect conditions on straight runs with few turns. For blowing one cable into innerduct or microduct, CBS Products gives area marks: lower 35%, including equality; upper 65%, excluding equality; reference 80%, beyond which air drag has progressively less of the surrounding space it needs. United Poly Systems (Atkore) gives a jetting range of 50 to 80 percent, basis unstated. The Fiber Optic Association gives a 76% upper mark, including equality, for microduct installation by jetting or blowing, basis unclear, attributed to an unnamed supplier. These figures differ and are not averaged. The cable and duct makers' product data decide.
The diameter ratio compares one item's outside diameter with the bore's inside diameter; area fill compares the items' combined cross-sections with the bore's cross-section. In millimeters, a 6 mm cable is an example input in a typed 10 mm duct: the diameter ratio is 60.0% and the area fill is 36.0%. Derived from the Plastics Pipe Institute's sizing relationship, a diameter ratio of 50% equals an area fill of 25%; the publisher does not print those percentages. A figure without its basis cannot be used.
Use the maker's data sheet. Offered SDR 11 printed average or nominal bores, inches by nominal size: 1: 1.055; 1-1/4: 1.338; 1-1/2: 1.533; 2: 1.917; 2-1/2: 2.321; 3: 2.826; 4: 3.633; 6: 5.348. Outside diameter minus two minimum walls gives larger bores, unused here: 2 in, 1.943 in; 4 in, 3.682 in. This page uses printed bores. When two separate sources differ by at most 0.002 in, the smaller is retained. Exception: 3 in SDR 11 retains one source's larger 2.826 in instead of the rule's 2.825 in. SDR 11 and 13.5 at 3/4 in and 5 in are withheld: separate sources disagree beyond 0.002 in. Enter the maker's bore.
Spare capacity needs an explicit purpose: a cable upgrade differs from reserving pathways for future providers. Draftech International establishes future demand with the owner before selecting conduit sizes and reserved space. The design records cable and conduit assumptions, proposed innerduct uses and expected additions, distinguishing present occupancy from future needs. During design review, we check that reserved capacity extends through the segments needed for expansion; a duct that stops short cannot provide the whole pathway. The documented design shows the owner what the arrangement supports and which changes need further engineering review.
Draftech International engineers your first 20,000 linear feet through permit approval, free. You pay agency permit fees and any required stamping fee. Active in 24 states. Available across all 50 U.S. states.