NESC AUDIT AND REMEDIATION DESIGN

Last reviewed: October 2026

Know which existing conditions meet the stated criteria and which need correction. Draftech's in-house engineers connect the review basis, supporting evidence, findings and remediation design in one accountable package.

[Get Your First 20,000 LF Free](https://draftech.com/free-design)

44K+

Miles of OSP Designed

2.6M+

Addresses Passed

24

Active States

600+

Engineers Nationwide

## NESC compliance engineering services backed by a documented record

Draftech provides National Electrical Safety Code (NESC) compliance engineering services for electric utilities, electric cooperatives, municipal pole owners and attachers reviewing existing poles or lines. You receive a documented code basis, clearance and strength evaluations, a violation and exception register, and engineering design for the corrections identified. All engineering is performed in-house, giving your team a single point of accountability from the initial review boundary through remediation design.

An informal assurance that a line complies with NESC leaves critical questions unanswered. Which edition governed? Which poles and spans were checked? What evidence described their condition? When a safety incident, claim, regulatory or RUS audit, or acquisition review exposes those gaps, the organization that relied on the assurance cannot show what it actually covered.

Within our [electric utility engineering practice](https://draftech.com/services/electric-utility-engineering/), this engagement gives those questions a documented answer. Each conclusion applies to specified facilities and checks, with the supporting evidence carried into the delivered package.

## Scope the review around the decision you need to make

A periodic compliance review needs a clear boundary before it can produce useful findings. We work with your engineering staff to define the poles, line or segment under review, the conditions to evaluate and the records available. Your team can then assess the findings against the actual assignment without assuming the review covers the entire system.

For an acquired system, inherited drawings and prior engineering reports may leave uncertainty about existing conditions. Draftech reviews those records against the agreed code basis. The resulting package lists specific correction needs for your capital planning discussions.

An ISP, carrier or contracted engineering vendor can also engage Draftech for an independent clearance or strength review before committing capital. This scope evaluates existing conditions without tying the engagement to a pending attachment application.

## Establish the code basis before evaluating conditions

Draftech determines and documents the governing NESC edition for the agreed review. We list the applicable owner construction standards separately and connect each checked condition to its controlling basis. The package makes clear whether a finding concerns an NESC requirement, an owner criterion or both.

That distinction matters when records carry different standards or an inherited report lacks its original review basis. Our engineers flag the discrepancy and seek the necessary clarification before issuing a conclusion that depends on it.

The code-basis determination also states the review limits. A clearance assignment covering selected spans does not establish the status of every condition on their supporting poles. We define included checks and exclusions at the start and preserve them in the final engineering opinion, so the issued conclusion matches the work performed.

## Evidence tied to each pole and span

We review client-supplied field data, drawings and prior engineering records against the information needed for the agreed evaluation. Each source must describe the pole or segment to which the finding will apply. A record with uncertain identity or an unexplained assumption becomes an engineering question before it controls the result.

Where current field information is needed, Draftech collects it through our [pole data collection service](https://draftech.com/services/pole-data-collection).

Our engineers keep supplied records separate from confirmed field evidence and flag gaps that could change a conclusion. If the available information cannot support a particular check, the package names that limitation and the information needed to resolve it. These open items are kept separate from confirmed findings, so your team can use supported results while arranging the remaining checks.

Incomplete records stay manageable. You can see which portion of the assignment needs additional evidence and why, instead of commissioning an undefined second review after receiving an inconclusive report.

## NESC clearance analysis and strength evaluation with traceable findings

Our engineers evaluate the existing conditions in the assignment against the documented code basis and owner criteria. Clearance checks cover vertical clearance over roads and driveways, separation between supply and communication space on the pole and at midspan, and clearance to buildings and signs, as included in the agreed scope. Strength evaluation checks whether the existing pole, crossarms and guying support the attachments and equipment now on the pole. Findings refer back to the affected pole or segment and the evidence used, keeping the technical result connected to an identifiable facility.

Your delivered review shows both results where both were commissioned, including any condition that could not be evaluated from the available evidence.

When a proposed correction changes a condition that affects another check, our engineers evaluate that relationship before issuing the design. For example, raising a conductor attachment to restore midspan separation changes the load on the pole and may require new guying, so we check the guy and pole as part of that design.

## Receive a violation and exception register you can act on

Draftech tracks the nonconforming conditions found during the review in a violation and exception register. Each entry names the pole or segment, the condition found, its engineering basis and the response needed. Open evidence questions are labeled as pending checks, separate from established nonconformances.

The register connects the review to action:

- Insufficient separation between a communication cable and the supply neutral at midspan is recorded with the supporting finding and the proposed raise or lower.
- For a down guy that no longer supports the current load, the entry connects the strength finding to the re-guying design.
- A span without measured sag data carries a request for the field measurement needed to complete its clearance check.
- Where an owner standard is stricter than the code basis, the entry lists the owner decision required for the proposed correction.

Your staff can use those entries to discuss remediation with the engineering team and follow pending decisions.

## Turn findings into specific remediation design

Our in-house engineers design clearance corrections, re-guying and re-framing where those actions address the violations found. The design names the physical change at the affected location and connects it to the evaluation supporting the remedy.

A general instruction to restore compliance leaves the actual design undefined. Draftech develops the correction around the documented existing condition and checks the affected clearance and strength relationships.

Where the finding calls for replacement, we document the replacement recommendation and hand it to [pole replacement engineering](https://draftech.com/services/electric-utility-engineering/pole-replacement-engineering/). That program handles inventory-wide prioritization and replacement design packages. The compliance review supplies the specific violation and the reason replacement was recommended.

The engagement concludes with one connected engineering package: the review boundary and code basis, supporting evaluations, tracked findings, remediation designs and outstanding decisions. The issued opinion states what the evidence supports within that boundary. The package labels remedies as proposed designs, not completed field corrections.

## When another Draftech service fits better

New line work belongs with [overhead distribution design](https://draftech.com/services/electric-utility-engineering/overhead-distribution-design/), where clearance checks support the proposed design. Incoming attachment applications to a pole owner belong with [joint use engineering](https://draftech.com/services/electric-utility-engineering/joint-use-engineering/). This standalone review addresses existing conditions when your organization needs a separate audit and remediation engagement.

For background on an attacher's application review, see our [NESC pole loading compliance guide for fiber attachments](https://draftech.com/blog/nesc-pole-loading-compliance-fiber-attachments). Engineers seeking guidance on documenting an individual pole-line clearance case can use our [aerial fiber clearance design guide](https://draftech.com/blog/aerial-fiber-clearance-design-requirements).

More in This Pillar

- [Electric Utility Engineering](https://draftech.com/services/electric-utility-engineering/)
- [Overhead Distribution Design](https://draftech.com/services/electric-utility-engineering/overhead-distribution-design/)
- [Underground Distribution (URD) Design](https://draftech.com/services/electric-utility-engineering/underground-distribution-design/)
- [Overhead-to-Underground Conversion](https://draftech.com/services/electric-utility-engineering/overhead-to-underground-conversion/)
- [Distribution Substation Design](https://draftech.com/services/electric-utility-engineering/distribution-substation-design/)
- [Joint Use for Pole Owners](https://draftech.com/services/electric-utility-engineering/joint-use-engineering/)
- [Pole Replacement Programs](https://draftech.com/services/electric-utility-engineering/pole-replacement-engineering/)
- [Grid Hardening Engineering](https://draftech.com/services/electric-utility-engineering/grid-hardening-engineering/)
- [Work Order Design](https://draftech.com/services/electric-utility-engineering/distribution-work-order-design/)
- [Co-op Broadband Engineering](https://draftech.com/services/electric-utility-engineering/electric-cooperative-broadband/)

Get Started

## Scope your existing-condition review

Bring Draftech the pole list or segment limits, available records, owner standards and the decision driving the assignment. Include prior findings and known information gaps. As your NESC engineering consultant, we will define the review boundary, evidence needs and remediation deliverables.

[Contact Draftech to scope your compliance review](https://draftech.com/contact)

[info@draftech.com](mailto:info@draftech.com) | [305-306-7407](tel:3053067407)

## Frequently Asked Questions

### Can we commission a review without proposing a new attachment?

Yes. This service covers standalone reviews of existing poles, lines or defined segments for owners and attachers. We establish the technical questions and facility limits around your periodic review, acquisition or capital decision.

### Who decides whether an exception is accepted?

Acceptance stays with the owner or other authorized party. An exception entry documents the condition and its disposition; it creates no code waiver and assigns no commercial responsibility. Draftech supplies the engineering recommendation for that party to review.

### Does the review certify the entire line as compliant?

No. Draftech issues an engineering opinion for the facilities and conditions in the agreed scope, not a certification of the line. It states the exclusions. Reviewing more of the line widens the opinion to the added facilities and checks; it remains an engineering opinion tied to that stated scope.

### Can Draftech design the corrections after finding violations?

Yes. Each remediation design is tied to its register entry, so you can trace a revised correction back to the condition it fixes.